GOTOP
 
APLEX Technology Inc - Industrial Panel PC, Water Proof Panel PC, Stainless Panel PC, Industrial Display, HMI, Industrial Automation provider 繁體中文 | 简体中文 | English | Sitemap
Home About us Products News Events Service & Support Contact us
Home | Applications
Introduce IP 65

First Number (Protection against solid objects)

Definition

Second number (Protection against liquids)

Definition

Protected against dust, limited ingress (no harmful deposit)

Protected against low pressure jets if water from all directions. Limited ingress permitted

Totally protected against dust

Protected against strong jets of water e.g. for use on shipdecks – limited ingress permitted

   

Protected against the effects of temporary immersion between 15cm and 1m. Duration of test 30 minutes.

   

Protected against long periods of immersion under pressure.

 
Introduce NEMA
  • NEMA (National Electrical Manufacturers Association)
  • NEMA Enclosure Rating andComparison to IP Code
  •   IP 65=NEMA4,4X
      IP 67=NEMA6,6P
IP 65 Technology
Test Method / Specification:

Test method:

Reference to IEC 60529 Edition 2.1 : 2001-02— IP 65

1. Test for protection against access to hazardous parts:

Test method : IEC 60529 Edition 2.1 : 2001-02— IP6X
 

The test-wire with 1.0mm in diameter and 100mm long is pushed against or inserted through any openings of the enclosure with the force specified in Table 6 in IEC 60529 Edition 2.1:2001-02. Examine whether the test wire touches the hazardous live parts inside the enclosure of not.

Test force:

1 N ±10%

2. Test for protection against solid foreign objects:

Test method:

IEC 60529 Edition 2.1:2001-02— IP6X (Dust test)
Type of dust: Talcum powder
The amount of dust: 2kg
The chamber size: 1m3
The maximum depression: -20 mbar
Test duration: 8 hours

3. Test for protection against water:

Test method:

Reference to IEC 60529 Edition 2.1:2001-02— IPX5

Test for protection against water:

 

Test means:

Spraying the enclosure from all practicable directions with a stream of water from a standard test nozzle as specified in test standard.
Internal diameter of the nozzle: 6.3mm

Delivery rate:

12.5 /min± 5%

Distance from nozzle to enclosure surface:

Between 2.5m and 3m

Core of the substantial stream:

Circle of approximately 40mm diameter at 2.5m distance from nozzle

Test duration:

3 minutes (minimum)

 
IP 65 Technology
IP 6X Test
IP X5 Test
 
IP 65 Approve
  • Inside the machine the pressure is 0.006Mpa positive. 60 seconds later, it drops to
      0.005Mpa.
  • Inside the machine the pressure is 0.010Mpa positive. 60 seconds later, it drops to
      0.008Mpa.
  • Inside the machine the pressure is 0.006Mpa positive. Bubbles emerge once the
      machine is put in the water.
  • Inside the machine there is no pressure. And when it is placed in the water, no
      bubbles are seen. After 30 minutes, still no water seepage takes place.
Introduce IP 65 Aplex Product
Type Totally IP 65 rating (全防水) IP 65 (water proof and anti-dust) on 5 sides, except I/O side) (五面防水)

NEMA 4/IP 65 compliant front panel(前防水)

LCD size 15” / 17” / 19” 12.1” / 15” / 17” / 19” 5.7” / 8” / 10.4” / 12.1” / 15” / 17” / 19”
Model Name APC ADP APC ADP APC AHM ADO

APC-3596
APC-3796
APC-3996
APC-3576
APC-3824

ADP-1156
ADP-1176

APC-3280/1
APC-3580/1
APC-3980/1
APC-3286/7
APC-3586/7
APC-3786/7
APC-3986/7

ADP-1xx0
ADP-1xx1
ADP-1xx4
ADP-1xx5

APC-3x11
APC-3x12
APC-3x13
APC-3x15

AHM-6xx1
AHM-6xx3
AHM-6xx4
AHM-6xx5

ADO-6050
ADO-6080
ADO-6100